The relationship between high resolution audiometry and tinnitugram in tinnitus patients
Main Article Content
Abstract
Introduction: tinnitus is a high prevalence, idiopathic condition, associated with hearing loss, which cannot be completely evaluated in conventional audiometry. The present study proposes the use of innovative methods for the subjective measurement of tinnitus and hearing thresholds with the use of tinnitugram and microaudiometry (automated audiometry). Objective: to analyzes the relationship between the tonal thresholds of microaudiometry and the tinnitugram. Methodology: a Retrospective descriptive study. Fifty-eight patients with tinnitus were studied between March 2018 and November 2019, with 67 frequency microaudiometry (range of 262-11 840 Hz) and the 134 frequency tinnitugram. A non-parametric test (Mann-Whitney) was used to compare the groups. Results: we found no significant relationship between the frecuency of tinnitus and the frequency of greatest decrease in microaudiometry. The frequency of the highest point of decrease in tonal thresholds was higher in
patients with tinnitus >8000 Hz (22.4 %) than in those <8000 Hz (p = 0.006). Conclusions: the thresholds of microaudiometry are not associated with the subjective characteristics of tinnitus, except in patients with tinnitus at frequencies >8000 Hz.
High frequencies should be included in audiological tests for tinnitus.
Downloads
Article Details
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Este artículo es publicado por la Revista Acta de Otorrinolaringología & Cirugía de Cabeza y Cuello.
Este es un artículo de acceso abierto, distribuido bajo los términos de la LicenciaCreativeCommons Atribución-CompartirIgual 4.0 Internacional.( http://creativecommons.org/licenses/by-sa/4.0/), que permite el uso no comercial, distribución y reproducción en cualquier medio, siempre que la obra original sea debidamente citada.
eISSN: 2539-0856
ISSN: 0120-8411
References
Bauer CA. Tinnitus. N Engl J Med. 2018;378(13):1224-31.
Henry JA, Dennis KC, Schechter MA. General review of tinnitus: prevalence, mechanisms, effects, and management. J
Speech Lang Hear Res. 2005;48(5):1204-35.
Bhatt JM, Lin HW, Bhattacharyya N. Prevalence, Severity, Exposures, and Treatment Patterns of Tinnitus in the United States. JAMA Otolaryngol Head Neck Surg. 2016;142(10):959-965.
Degeest S, Corthals P, Vinck B, et al. Prevalence and characteristics of tinnitus after leisure noise exposure in young
adults. Noise Health. 2014;16(68):26-33.
Newman CW, Jacobson GP, Spitzer JB. Development of the Tinnitus Handicap Inventory. Arch Otolaryngol Head Neck
Surg. 1996;122(2):143-8.
Galves EF, Pegalajar CJ, Espinosa JM. La evaluación del malestar psicológico asociado al acúfeno mediante el Tinnitus
Reaction Questionnaire: adaptación a la población española. Análisis y Modificación de Conducta. 32(145):621-41.
Shojaeemend H, Ayatollahi H. Automated Audiometry: A Review of the Implementation and Evaluation Methods. Health
Inform Res. 2018;24(4):263-75-
Eggermont JJ. Tinnitus and neural plasticity (Tonndorf lecture at XIth International Tinnitus Seminar, Berlin, 2014). Hear Res. 2015;319:1-11.
Shekhawat GS, Searchfield GD, Stinear CM. The relationship between tinnitus pitch and hearing sensitivity. Eur Arch
Otorhinolaryngol. 2014;271(1):41-8.
Pan T, Tyler RS, Ji H, et al. The relationship between tinnitus pitch and the audiogram. Int J Audiol. 2009;48(5):277-94.
Keppler H, Degeest S, Dhooge I. The relationship between tinnitus pitch and parameters of audiometry and
distortion product otoacoustic emissions. J Laryngol Otol. 2017;131(11):1017-1025.
Kaltenbach JA, Zhang JS, Zacharek MA. Neural correlates of tinnitus. En: Snow JB, editor. Tinnitus: theory and management. Ontario: BC Decker Inc, Hamilton; 2014. p. 141-61.
Ristovska L, Zora J, Vase S. Psychoacoustic Characteristics of Tinnitus in Relation to Audiometric Profile. Archives of
Acoustics. 2019;44(3):419-428.
Gerken GM. Central tinnitus and lateral inhibition: an auditory brainstem model. Hear Res. 1996;97(1-2):75-83.
König O, Schaette R, Kempter R, et al. Course of hearing loss and occurrence of tinnitus. Hear Res. 2006;221(1-2):59-64.
Weisz N, Hartmann T, Dohrmann K, et al. High-frequency tinnitus without hearing loss does not mean absence of deafferentation. Hear Res. 2006;222(1-2):108-14.